Shop

HF-1200V5

Free switching of machine or manual control

High precious veterinary anaesthesia equipment system.It is suitable for animal hospital ,pet clinic and animal laboratory.This technical index of animal anaesthesia machine can meet the needs of general anesthesia and medical research on mice,dogs,cats,rabbits,monkeys,pigs,sheep and other animals,etc.

Main Parameters

Main unit:
Working mode closed,half-closed,open,half-open
Driving mode Pneumatically and electrically
Application Animal within 100kg
Anesthesia vaporizer Sevoflurane,Isoflurane,Halothane
Oxygen flush 25L/min-75L/min
Gas source pressure Oxygen 0.25Mpa-0.65Mpa
Ventilator:
Working mode Machine-control,Manual
Ventilation mode IPPV
Bellow 0-300ml,50-1500ml
Screen digital display
Monitor Tidal volume,breathing rate,I:E,peak pressure
Tidal volume 20ml/min-1500ml/min
Adjustment breathing rate 4-60bpm
Minute ventilation No less than 18L/min
Airway pressure upper limit 2-6kpa
Airway pressure lower limit 0.5-2kpa
Alarm:
Low oxygen supply pressure alarm
Alrway pressure upper limit alarm
Airway pressure lower limit alarm, Mute
Anesthesia Vaporizer:
Concentration range:
Isoflurane 0.2-5%
Sevoflurane 0.2-8%
Halothane 0.2-5%
Flow range 0.2-15L/min
Filling volume for agent about 340ml with dry wick
Filling volume for agent about 300ml with moist wick
Mounting type Cagemout cmpatiable(optional)
Flowmeter:
Oxygen flowmeter special for veterinary
Flow range 0-5L/min

 

General Purpose for Small and Large Animals

  • Oxygen flush button:Rapidly supply oxygen to animals
  • Special for big and small animals(0-300ml,300-1500ml),Interface of non-breathing circuit:Suitable for small animal

Safe and Reliable

  • Anesthesia vaporizer:the output concentration is not affected by changes in flow,pressure and humidity,equipped with a safety lock device to prevent the leakage of anesthetics
  • Flowmeter:0.1-5L,adjust the flow of inhaled oxygen
  • Exhaust gas absorption tank:built-in activated carbon absorbs anesthetic exhaust gas,reusable

Fast Response Time and High Accuracy

  • Professional airtight breathing circuit design,provide the stable gas anesthesia,save anesthesia gas consumption,to ensure a clean operating room and laboratory environment
  • With Oxygen flush function to ensure that clinical anesthesia demand and oxygen supply demand
  • Anaesthesia CO2 absorber assembly has no dead angle design
  • The CO2 absorber supports both open loop and closed loop anaesthesia design and provides independent access

Contact us

If you are interested in our products or services, please leave your valuable information and we will contact you as soon as possible.